| If this is not your name, click here. | | |
| | Contact Us | Order Now | Journals | Bookstore | Register a colleague | | |
| | | ![]() Closed-Loop Insulin Delivery System Can Improve Glucose Control in Young Patients With Type 1 Diabetes NEW YORK -- February 4, 2010 -- Use of ‘artificial pancreas’ closed-loop insulin delivery systems, in which insulin is delivered in response to changing blood sugar levels, can improve blood sugar control in patients with type 1 diabetes, according to a study published online first and appearing in an upcoming edition of The Lancet. Continuous glucose monitoring devices and insulin pumps can be combined to form closed-loop systems. Insulin is then delivered according to real-time sensor glucose data, as directed by a control algorithm, rather than at preprogrammed rates. Few closed-loop prototypes have been developed and progress has been hindered by suboptimum accuracy and reliability of monitoring devices, slow absorption of subcutaneously administered rapid-acting insulin analogues, and inadequate control algorithms. In this study, Roman Hovorka, MD, Institute of Metabolic Science, University of Cambridge and Addenbrooke’s Hospital, Cambridge, United Kingdom, and colleagues aimed to establish whether closed-loop systems reduce risk of nocturnal hypoglycaemia and achieve good glucose control in children and adolescents, even after variable evening meal intake and differing exercise patterns. The researchers studied 17 children and teenagers aged 5 to 18 years with type 1 diabetes during 54 nights in hospital. The team measured how well the artificial pancreas system controlled glucose levels compared with the children’s regular continuous subcutaneous insulin infusion (CSII) pump, which delivers insulin at preselected rates. The study included nights when the children went to bed after eating a large evening meal or having done early evening exercise. Both are challenging to manage, a large evening meal because it can lead to so-called ‘insulin stacking’ and, as a result, a potentially dangerous drop in blood glucose levels later in the night, and late afternoon or early evening exercise because it increases the body’s need for glucose in the early morning and can therefore increase the risk of night time hypoglycaemia. The data showed that children with the artificial pancreas maintained blood glucose levels in the normal range for 60% of the time, compared with 40% for the CSII. The artificial pancreas halved the time that blood glucose levels fell below 3.9mmol/l. It also prevented blood glucose falling below 3.0mmol/l, which is defined as significant hypoglycaemia, compared with 9 hypoglycaemia events in the control studies. “Our results show that overnight manual closed-loop insulin delivery can improve glucose control and reduce risk of hypoglycaemia in young patients with type 1 diabetes,” the authors wrote. “Closed-loop systems could transform management of type 1 diabetes, but their introduction is likely to be gradual, starting from straightforward applications such as shutting off of the pump at low glucose concentrations or overnight closed-loop delivery, proceeding to more complex applications providing 24-hour control. Overnight closed-loop delivery is appealing because it addresses the issue of nocturnal hypoglycaemia.” “Advancements in glucose-sensing technologies could further improve performance of closed-loop systems,” the authors concluded. “Fully automated closed-loop delivery will need wireless data transmission to replace manual control of the pump by nurses. These technological steps are important but routine and should not affect closed-loop performance.”
SOURCE: The Lancet
|